![]() |
||
---|---|---|
.. | ||
.gitignore | ||
Dockerfile | ||
LICENSE | ||
README.md | ||
acquisition.py | ||
byte_swap.py | ||
config.py | ||
example.env | ||
gateway.py | ||
main.py | ||
myems-modbus-tcp.service | ||
requirements.txt | ||
run.sh | ||
test.py |
README.md
MyEMS Modbus TCP Service
Introduction
This service is a component of MyEMS to acquire data from Modbus TCP devices.
Prerequisites
mysql-connector-python
modbus_tk
schedule
python-decouple
Quick Run for Development
cd myems/myems-modbus-tcp
pip install -r requirements.txt
cp example.env .env
chmod +x run.sh
./run.sh
Installation
Option 1: Install myems-modbus-tcp on Docker
In this section, you will install myems-modbus-tcp on Docker.
- Copy source code to root directory
On Windows:
cp -r myems/myems-modbus-tcp c:\
cd c:\myems-modbus-tcp
On Linux:
cp -r myems/myems-modbus-tcp /
cd /myems-modbus-tcp
- Create .env file based on example.env file
Manually replace 127.0.0.1 with real HOST IP address.
cp example.env .env
- Build a Docker image
docker build -t myems/myems-modbus-tcp .
- Run a Docker container
On Windows host, bind-mount the .env to the container:
docker run -d -v c:\myems-modbus-tcp\.env:/code/.env:ro --restart always --name myems-modbus-tcp myems/myems-modbus-tcp
On Linux host, bind-mount the .env to the container:
docker run -d -v /myems-modbus-tcp/.env:/code/.env:ro --restart always --name myems-modbus-tcp myems/myems-modbus-tcp
-
-d Run container in background and print container ID
-
-v If you use -v or --volume to bind-mount a file or directory that does not yet exist on the Docker host, -v creates the endpoint for you. It is always created as a directory. The ro option, if present, causes the bind mount to be mounted into the container as read-only.
-
--restart Restart policy to apply when a container exits
-
--name Assign a name to the container
The absolute path before colon is for path on host and that may vary on your system. The absolute path after colon is for path on container and that CANNOT be changed. By passing .env as bind-mount parameter, you can change the configuration values later. If you changed .env file, restart the container to make the change effective.
If you want to immigrate the image to another computer,
- Export image to tarball file
docker save --output myems-modbus-tcp.tar myems/myems-modbus-tcp
- Copy the tarball file to another computer, and then load image from tarball file
docker load --input .\myems-modbus-tcp.tar
Installation Option 2: Online install on Ubuntu server with internet access
In this section, you will install myems-modbus-tcp on Ubuntu Server with internet access.
cp -r myems/myems-modbus-tcp /myems-modbus-tcp
cd /myems-modbus-tcp
pip install -r requirements.txt -i http://mirrors.aliyun.com/pypi/simple/ --trusted-host mirrors.aliyun.com
Copy exmaple.env file to .env and modify the .env file:
cp /myems-modbus-tcp/example.env /myems-modbus-tcp/.env
nano /myems-modbus-tcp/.env
Setup systemd service:
cp myems-modbus-tcp.service /lib/systemd/system/
Enable the service:
systemctl enable myems-modbus-tcp.service
Start the service:
systemctl start myems-modbus-tcp.service
Monitor the service:
systemctl status myems-modbus-tcp.service
View the log:
cat /myems-modbus-tcp.log
Installation Option 3: Offline install on Ubuntu server without internet access
Download and install MySQL Connector:
cd ~/tools
wget https://cdn.mysql.com//Downloads/Connector-Python/mysql-connector-python-8.0.28.tar.gz
tar xzf mysql-connector-python-8.0.28.tar.gz
cd ~/tools/mysql-connector-python-8.0.28
python3 setup.py install
Download and install Schedule
cd ~/tools
git clone https://github.com/dbader/schedule.git
cd ~/tools/schedule
python3 setup.py install
Download and install Python Decouple
cd ~/tools
git clone https://github.com/henriquebastos/python-decouple.git
cd ~/tools/python-decouple
python3 setup.py install
Download and install modbus-tk
cd ~/tools
git clone https://github.com/pyserial/pyserial.git
cd ~/tools/pyserial
python3 setup.py install
git clone https://github.com/ljean/modbus-tk.git
cd ~/tools/modbus-tk
python3 setup.py install
Install myems-modbus-tcp service
cp -r myems/myems-modbus-tcp /myems-modbus-tcp
cd /myems-modbus-tcp
Create .env file based on example.env and edit the .env file if needed:
cp /myems-modbus-tcp/example.env /myems-modbus-tcp/.env
nano /myems-modbus-tcp/.env
Setup systemd service:
cp myems-modbus-tcp.service /lib/systemd/system/
Enable the service:
systemctl enable myems-modbus-tcp.service
Start the service:
systemctl start myems-modbus-tcp.service
Monitor the service:
systemctl status myems-modbus-tcp.service
View the log:
cat /myems-modbus-tcp.log
Add Data Sources and Points in MyEMS Admin UI
NOTE: If you modified Modbus TCP data sources and points, please restart this service:
systemctl restart myems-modbus-tcp.service
Input Data source protocol:
modbus-tcp
Data source connection example:
{"host":"10.9.67.99","port":502}
Point address example:
{"slave_id":1, "function_code":3, "offset":0, "number_of_registers":2, "format":"<f", "byte_swap":true}
Address
slave_id
The slave ID
function_code
01 (0x01) Read Coils
02 (0x02) Read Discrete Inputs
03 (0x03) Read Holding Registers
04 (0x04) Read Input Registers
23 (0x17) Read/Write Multiple registers
offset
The starting register address specified in the Request PDU
number_of_registers
The number of registers specified in the Request PDU
format
Use python3 library struct to format bytes. Python bytes objects are used to hold the data representing the C struct and also as format strings (explained below) to describe the layout of data in the C struct.
The optional first format char indicates byte order, size and alignment: @: native order, size & alignment (default) =: native order, std. size & alignment <: little-endian, std. size & alignment >: big-endian, std. size & alignment !: same as >
The remaining chars indicate types of args and must match exactly; these can be preceded by a decimal repeat count: x: pad byte (no data); c:char; b:signed byte; B:unsigned byte; ?: _Bool (requires C99; if not available, char is used instead) h:short; H:unsigned short; i:int; I:unsigned int; l:long; L:unsigned long; f:float; d:double.
Special cases (preceding decimal count indicates length): s:string (array of char); p: pascal string (with count byte). Special cases (only available in native format): n:ssize_t; N:size_t; P:an integer type that is wide enough to hold a pointer.
Special case (not in native mode unless 'long long' in platform C): q:long long; Q:unsigned long long
Whitespace between formats is ignored.
byte_swap
A boolean indicates whether or not to swap adjacent bytes.
Swap adjacent bytes of 32bits(4bytes) or 64bits(8bytes).
This is not for little-endian and big-endian swapping, and use format for that.
The option is effective when number_of_registers is ether 2(32bits) or 4(64bits),
else it will be ignored.
References
[1]. http://myems.io
[2]. http://www.modbus.org/tech.php
[3]. https://github.com/ljean/modbus-tk
[4]. https://docs.python.org/3/library/struct.html#format-strings